0230FR

VCL Membrane

Class A - EN 13501-1

A VCL membrane that has excellent air and vapour-tightness properties which make it ideally suited to improving the airtightness, moisture management and energy efficiency of buildings.  Read more

  • 3rd Party Certified 3rd Party Certified
  • Class A Class A
  • EI60 Certified EI60 Fire Test Component
  • EI120 Certified EI120 Fire Test Component
  • EN 1928 - EN 13984 EN 1928 - EN 13984
Enquire Now

Downloads

OBEX CORTEX 0230FR VCL Kiwa Cert

OBEX CORTEX 0230FR VCL Membrane Installation Guide

OBEX CORTEX 0230FR VCL - Vapour Control Layer Class A2 TDS

OBEX CORTEX 0230FR VCL - Vapour Control Layer Class A2 SDS

OBEX CORTEX 0230FR VCL - Vapour Control Layer Class A2 DoP

Product Description

OBEX CORTEX 0230FR Class A2 VCL membrane has excellent air and vapour-tightness properties which make it ideally suited to improving the airtightness, moisture management and energy efficiency of buildings. 

It is installed on the warm side of the insulation and provides an air and vapour-tight barrier, preventing warm air and moisture from passing through the external wall and forming interstitial or surface condensation within the cavity.

The VCL Membrane is normally bonded to the steel framing with OBEX CORTEX Double-Sided Tape before the plasterboard layer is applied.  Applications may vary depending on the construction build up.  The OBEX Technical team can help with any application queries.

The membrane is installed using the CORTEX 0825 Installation Kit which includes 2 rolls of CORTEX 0824FR Double-Sided Tape and 6 rolls of single sided CORTEX 0823FR UV Façade Tape.

Typical Uses

  • Class A2 VCL membrane for use as an internal Vapour Control Layer.

Product Specs

Roll size

1200mm x 50m

Thickness

0.18mm (+/-0.03)

Colour

Silver/white

Technical Specs

Harmonised Standard

EN 13984

3rd Party Certification

KIWA - BAW-22-246-P-A-UK

Fire Classification | EN 13501-1

A2-s1,d0

Watertightness | EN 1928

Pass – 2 kPa for 24 hours

Resistance to air penetration | EN 12114

Net leakage: 0m³/h/m²(+/- 100Pa)

Water vapour transmission (Sd value) | EN 1931

2575.35m

UV resistance

High

Vapour resistance

12,874 MNs/g

Tensile Strength | EN 12311-2

Longitudinal: 1362 N/50mm, Transverse: 1349 N/50mm

Tear strength (nail shank) | EN 12310-1

Longitudinal: 150N Transverse: 150N

Elongation | EN 12311-2

Longitudinal: 2.8% Transverse: 3.8%

Low temperature flexibility | EN1109

-40°C

Product Order Codes

Product CodesProduct DescriptionWidthLengthBox Quantity
20.0230.023OBEX CORTEX 0230FR Vapour Control Layer - Class A2-s2,d0 / W11200mm50m1

Enquire now